9kW Output:20~58Vdc/150A

Product Features
High efficiency: Reduces energy loss, meets energy conservation and emission reduction requirements, and cuts electricity costs for customers.
High power density: Saves customer space and reduces system costs.
Wide input and output voltage ranges: Suitable for most different input and output voltage scenarios.
Hot-swappable: Convenient to use and reduces maintenance costs.
Built-in reverse protection with failure self-isolation: Greatly improves system reliability.
DSP digital control: Fewer components, higher environmental stability, higher reliability, and easier system expansion.
Environmental adaptation: Wide operating temperature range of -40°C ~ 75°C, suitable for harsh working environments.
Low input harmonics: Reduces grid pollution and offers stronger grid adaptability.
Product Parameters
|
Item |
Specification |
|
|
General |
Model |
TR48-9000e |
|
Dimensions |
240 x 398 x 85mm |
|
|
Weight |
Approx. 8kg |
| Item | Specification | |
|---|---|---|
| DC Output Specifications | Rated Output Power | 9kW |
| Rated Output Voltage | 100Vdc | |
| Rated Output Current | 150A | |
| Output voltage range | 20VDC ~ 58VDC | |
| Performance Guarantee | 42V ~ 58V | |
| Current limiting adjustment range | 10% to 110% stepless adjustment | |
| Peak-to-peak ripple | ≤ 200 mV | |
| Telephone weighing noise | < 2 mV | |
| Voltage regulation accuracy | ≤ ±0.5% | |
| Steady flow accuracy | ≤ ±1% | |
| Flow sharing accuracy | ≤ ±5% | |
| Conversion efficiency | ≥ 95% |
| Item | Specification | |
|---|---|---|
| AC Input | Rated input voltage Three-phase | 380Vac / 480Vac |
| Input voltage range | 305Vac ~ 530Vac (full load) | |
| Reduced input range | 305Vac ~ 260Vac (linearly descent to half load) | |
| Input current | < 16A | |
| Input frequency | 45Hz ~ 65Hz | |
| Power factor PF | ≥ 0.99 | |
| Harmonic Distortion (THD) | ≤ 5% | |
| Input protection | Fuse and lightning protection circuits |
|
Item |
Specification |
|
|
Environmental conditions |
Operating temperature |
-40℃ to 45℃ (full load operation), derating from 45℃ to 65℃ |
|
Storage temperature |
-40℃ to 75℃ |
|
|
relative humidity |
0% ~ 95% |
|
|
Altitude |
≤ 2000m full load output |
|
Item |
Specification |
|
|
Safety and Reliability |
Input pressure resistance to housing |
2500VAC / 3535VDC (1 minute)
|
| Input to output withstand voltage |
3000VAC / 4242VDC (1 minute) |
|
| Mean Time Between Failures (MTBF) |
>120,000 hours |
|
|
Communication and System Functions |
Communication Interface |
CAN |
|
Maximum number of parallel connections |
60 units | |
|
Status monitoring |
Uploaded via CAN communication and indicated by panel LEDs. | |
|
Output protection |
Positive and negative electrode protection |