10kW Output: 65~135Vdc/75A Input: 3P 200Vac_Japan Standard

Product Features
High efficiency: Reduces energy loss, meets energy conservation and emission reduction requirements, and cuts electricity costs for customers.
High power density: Saves customer space and reduces system costs.
Wide input and output voltage ranges: Suitable for most different input and output voltage scenarios.
Hot-swappable: Convenient to use and reduces maintenance costs.
DSP digital control: Fewer components, higher environmental stability, higher reliability, and easier system expansion.
Comprehensive fault self-detection and alerts: Rich fault detection functions for convenient customer maintenance.
Environmental adaptation: Wide operating temperature range of -40°C ~ 75°C, suitable for harsh working environments.
Low input harmonics: Reduces grid pollution and offers stronger grid adaptability.
Product Parameters
|
Item |
Specification |
|
|
General |
Model |
EVR130-10000L |
|
Dimensions |
240mm (W) × 85mm (H) × 398mm (D) |
|
|
Weight |
Approx. 8kg |
|
Item |
Specification |
|
|
DC Output Specifications |
Rated Output Power |
10kW |
|
Rated Output Current |
75A | |
|
Output Voltage Range |
65VDC~135VDC | |
|
Constant Power Range |
10%~11 0% (Stepless) | |
|
Peak-to-Peak Noise |
≤1% | |
|
Voltage Regulation Accuracy |
≤±1% | |
|
Current Regulation Accuracy |
≤±1% | |
|
Current Sharing |
≤±5% | |
|
Efficiency |
≥93.5%(Full Load); ≥95% (Peak) |
|
Item |
Specification |
|
|
AC Input |
Rated Input Voltage |
3-Phase 200Vac/240Vac |
|
Input Voltage Range |
176Vac~250Vac (Full load); |
|
|
Input Current |
<45A | |
|
Frequency |
45Hz~65Hz | |
|
Power Factor (PF) |
≥0.99 | |
|
Total Harmonic Distortion (THD) |
≤5% | |
|
Input Protection |
Fuses; Surge Protection Circuit (SPD) |
|
Item |
Specification |
|
|
Operating Environment |
Coolant Temperature |
-40℃~55℃(Normal); 55℃~75℃(Derating) |
|
Storage Temperature |
-40℃~75℃ |
|
|
Relative Humidity |
0~95% |
|
|
Altitude |
Full load output below 2000m |
|
Item |
Specification |
|
|
Reliability & Compliance |
Dielectric Strength |
Input to Chassis: Withstands 2500VAC (50Hz, RMS) or equivalent 3535VDC for 1 minute. Input to Output: Withstands 3000VAC (50Hz, RMS) or equivalent 4242VDC for 1 minute. Output to Chassis: Withstands 1500VAC (50Hz, RMS) or equivalent 2121VDC for 1 minute. |
| MTBF |
>120,000 Hours |
|
|
Communication |
Communication Interface |
CAN |
| Output positive and negative insurance protection. | ||
| Alarms and status are reported to the monitoring system via CAN bus, complemented by three front-panel LED indicators. | ||