10kW Output: 30~105Vdc/100A

Product Features
High efficiency: Reduces energy loss, meets energy conservation and emission reduction requirements, and cuts electricity costs for customers.
High power density: Saves customer space and reduces system costs.
Built-in reverse protection with failure self-isolation: The module output integrates relays and pre-charge circuits for anti-reflux function, effectively improving system reliability. It also features a built-in 12V/2A auxiliary power supply to reduce system complexity.
Comprehensive fault self-detection and alerts: Rich fault detection functions for convenient customer maintenance.
High protection: Full potting protection scheme enhances product reliability.
DSP digital control: Fewer components, higher environmental stability, higher reliability, and easier system expansion.
Environmental adaptation: Wide operating temperature range of -40°C ~ 75°C, suitable for harsh working environments.
Low input harmonics: Reduces grid pollution and offers stronger grid adaptability.力
Product Parameters
|
Item |
Specification |
|
|
General |
Model |
ICR100-10000C |
|
Dimensions |
240mm (W) × 85mm (H) × 429mm (D, including handle and terminals) |
|
|
Weight |
Approx. 7kg |
|
|
Output Rating |
100V@100A |
|
|
Output Voltage Range |
30V - 100V (Constant power: 91V - 100V, 410kW) |
|
|
Output Current Range |
0A~110A (T≤55℃) |
|
Item |
Specification |
|
|
DC Output |
Peak-to-Peak Noise |
≤±1% |
|
Voltage Regulation Accuracy |
≤±0.5% | |
|
Current Regulation Accuracy |
≤±1% | |
|
Current Sharing |
≤±5% | |
|
Efficiency |
≥95%(Peak) | |
|
12V Auxiliary Power |
12V/2A;12V/3A(1 min) |
|
Item |
Specification |
|
|
AC Input |
Rated Input Voltage |
3-Phase 380Vac / 480Vac |
|
Input Voltage Range |
323Vac~530Vac (Full load); |
|
|
Input Current |
<20A | |
|
Frequency |
45Hz~65Hz | |
|
Power Factor (PF) |
≥0.99 | |
|
Total Harmonic Distortion (THD) |
≤5% | |
|
Input Protection |
Fuses; Surge Protection Circuit (SPD) |
|
Item |
Specification |
|
|
Operating Environment |
Coolant Temperature |
-40℃~55℃(Normal); 55℃~80℃(Derating) |
|
Storage Temperature |
-40℃~75℃ |
|
|
Relative Humidity |
0~95% |
|
|
Altitude |
Full load output below 2000m |
|
Item |
Specification |
|
|
Reliability & Compliance |
Dielectric Strength |
Input to output, input to communication: DC 4242V, 1min Input to housing: DC 3535V, 1min Output to housing, output to communication: DC 2121V, 1min Communication to housing: DC 707V, 1min; |
|
MTBF |
>120,000 Hours |
|
|
Safety Standards |
Compliant with IEC62477-1 |
|
|
Communication |
Communication Interface |
CAN |
|
Max. Units in Parallel |
60 units |
|
|
Integrated output discharge function. |
||
|
Alarms and status are reported to the monitoring system via CAN bus, complemented by three LED indicators and two buttons on the front panel. |
||